G1013 HART to FF Gateway

G0306 Modbus to DP Gateway

G0307 Modbus to PA Gateway

G0313 Modbus to FF Gateway

G0310 Modbus to HART Gateway

G1003 HART to Modbus Gateway

G1013 HART to FF Gateway

MH105 MODBUS to HART Gateway

G1013 HART to FF Gateway, designed by Microcyber Corporation is a gateway device for HART protocol and FF protocol. As HART master, G1013 HART to FF Gateway communicates with HART slave via HART interface, it can convert dynamic variables in the device to FF device variables output. 

G0306 gateway can realize interconnection from Modbus RTU device to fieldbus PROFIBUS DP, and protocol conversion between Modbus RTU and PROFIBUS DP/V0. The user can make multiple Modbus RTU devices access to PROFIBUS DP network only by GSD file configuration.

24V DC power supply, standard PROFIBUS DP interface, rapid to diagnose device working state by indicator lights, easy to use.

G0306 has combined high reliability and flexibility, being indispensable internet tool of all industries of system integrators and plant operating personnel.

Features
Support 31 Modbus RTU slave devices at most
Be tallied with PROFIBUS-DP/V0 protocol stipulations
Support 244 input, 244 output, 244 parameters at most
Modbus RTU and PROFIBUS DP configured flexibly by GSD files
Transparent data transfer of Modbus RTU and PROFIBUS DP
PROFIBUS DP address set up by hardware
35mm rail, easy to install
Frequency converter, motor start protection device, transmitters, intelligent measuring device and instrument, etc. with MODBUS protocol interface

 

Specifications
Working Temp.
-20 ... +70 °C
Storage Temp.
-40 °C ... +85 °C
Working Pressure
9 … 36 V / 14 mA@ 24 V 
Dimension (L x W x H)

112.5 x 52 x 70 mm (without connector)
Interface
RS485
Indicator Light
SYS, APL, L/A, Rx/Tx, bus-specific
Weight
150 g
Protocol before conversion
Modbus
Protocol after conversion
DP
EMC
GB/T 18268.1
Noise Interference
EN 61131-2:2003
Installation
DIN-Rail, EN-50022 35mm x 7,5mm

 

G0307 realizes converting from Modbus RTU to PROFIBUS PA, makes multiple Modbus RTU slave devices access to PROFIBUS PA network. All related Modbus configuration is done by EDD, powerful, convenient and quick. Can be widely used in many industry fields.

Features
Support 4 Modbus RTU slave devices’ access at most
Each Modbus RTU slave device is assigned 4 function blocks by default, each function block is one piece.
Modbus RTU interface can configure bus terminal, 24VDC external power supply required
Support PROFIBUS PA 3.02
Configure PROFIBUS address by software or hardware
PROFIBUS PA is powered by bus
4 function blocks, AI/AO/DI/DO, each is four pieces, totally 16 function blocks, ahead of similar products
Support GSD files, total 16 channels, each has one fixed function block, each function block can be configured a variety of modules

 

Specifications
Working Temp.
-20 ... +70 °C
Storage Temp.
-40 °C ... +85 °C
Working Pressure
9 … 36 V / 14 mA@ 24 V
Dimension (L x W x H)

112.5 x 52 x 70 mm (without connector)
Interface
RS485
Indicator Light
SYS, APL, L/A, Rx/Tx, bus-specific
Weight
150 g
Protocol before conversion
Modbus
Protocol after conversion
PA
EMC
GB/T 18268.1
Noise Interference
GB 9254
Installation
DIN-Rail, EN-50022 35mm x 7,5mm

 

G0313 realizes converting from Modbus RTU to FF H1. G0313 can effectively reduce development difficulty to transform from Modbus device to FF device, easily upgrade Modbus RTU device. Sophisticated design, easily installed on DIN rail in control box or protection box on site. To connect Modbus slave device via simple configuration, so as to realize converting from Modbus RTU to FF. One gateway can take at most four Modbus RTU slave devices, cost-effective. To judge whether G0313 works in normal by LED indicators during field application.

Support 4 Modbus RTU slave devices’ access at most
Support AI/AO/DI/DO, each support 8 channels
1 Modbus transducer block
4 PID function blocks
1 RES function block tallied with FF standard
Modbus RTU device upgrade
Side wiring diagram and parameter description
DIN rail installation
Working status indicating LED

 

Specifications
Working Temp.
-20 ... +70 °C
Storage Temp.
-40 °C ... +85 °C
Working Pressure
9 … 36 V / 14 mA@ 24 V
Dimension (L x W x H)

114.5 x 22.5 x 99 mm (without connector)
Interface
RS485
Indicator Light
SYS, APL, L/A, Rx/Tx, bus-specific
Weight
150 g
Protocol before conversion
Modbus
Protocol after conversion
FF
EMC
GB/T 18268.1
Noise Interference
GB 9254
Installation
DIN-Rail, EN-50022 35mm x 7,5mm

 

G0310 Modbus to HART Gateway, designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output. 

Features
Be tallied with HART7.0
HART slave and Modbus master mode
4~20mA analog signal overlay HART digital signal
Support 1 Modbus slave device
Support 6 device variables and 4 dynamic variables
Configure gateway by HART interface
Write protect user data
Support high/low alarm current
RS485 Modbus interface
LED power and communication indicating
Standard DIN rail installation

 

Specifications
Working Temp.
-20 ... +70 °C
Storage Temp.
-40 °C ... +85 °C
Working Pressure
12 … 42 V 
Dimension (L x W x H)

114.5 x 22.5 x 99 mm (without connector)
Interface
RS485
Indicator Light
SYS, APL, L/A, Rx/Tx, bus-specific
Weight
150 g
Protocol before conversion
Modbus
Protocol after conversion
HART
EMC
GB/T 18268.1
Noise Interference
GB 9254
Installation
DIN-Rail, EN-50022 35mm x 7,5mm

G1003 gateway realizes protocol converting from HART to Modbus RTU / ASCII. Supporting to connect multi HART slave devices into Modbus network. In the gateway, HART terminal is master station, Modbus terminal is slave station.

Features
Be tallied with HART7.0
HART master and Modbus slave mode
4~20mA analog signal overlay HART digital signal
Support 15 HART slave device
Configure gateway by special software
Write protect user data
RS485 Modbus interface
LED power and communication indicating
Standard DIN rail installation

 

Specifications
Working Temp.
-20 ... +70 °C
Storage Temp.
-20 ... +70 °C
Power Supply
9~30VDC
Dimension (L x W x H)

114.5 x 22.5 x 99 mm (without connector)
Modbus Interface
RS-232/RS-422/RS485
HART Interface
HART digital signal
Indicator Light
SYS, APL, L/A, Rx/Tx, bus-specific
Weight
150 g
Protocol before conversion
HART
Protocol after conversion
Modbus
EMC
GB/T 18268.1
Noise Interference
GB 9254
Installation
DIN-Rail, EN-50022 35mm x 7,5mm

 

G1013 HART to FF Gateway, designed by Microcyber Corporation is a gateway device for HART protocol and FF protocol. As HART master, G1013 HART to FF Gateway communicates with HART slave via HART interface, it can convert dynamic variables in the device to FF device variables output. 

NCS-MH105 is a converter device for MODBUS-RTU protocol to HART protocol. As a MODBUS host, NCS-MH105 communicates with the device with MODBUS-RTU communication ability, it converts the data in the device to HART device variables, and supports 4~20mA current output.

NCS-MH105 converter supports 4 dynamic variables, 6 device variables, all HART universal commands, common practice HART commands and standard MODBUS-RTU protocol. The mechanism size is 96 mm * 56 mm, which not only matches standard Adam module housing, also can be installed to device through positioning hole.

HART Bus gives power supply to NCS-MH105 converter. RS485 electrical interface requires an external 5V power supply.
   
NCS-MH105 Application:
Gas detectors
Analyzers
Positioners
Any smart device with MODBUS protocol

 

Compliant with HART 6.0 standard, provide HART communication ability to MODBUS device
Support all HART universal commands and common practice HART commands
Support device specific commands on demand
Support HART multidrop mode
Support HART communication burst mode
Support handheld 375/475
Electrical interface connected withMODBUS device supports TTL level, RS485 and RS232

Physical Parameters:
Bus signal: 4~20mA output with HART protocol,    
digital communication
Bus power supply:11.9 ~ 42V
Operating temperature: -40 ~ 85℃
Humidity range: 5% ~ 95%,non-dew
Mechanism size: 120mm × 54mm(can be customized)

Supportive MODBUS Communication Parameters:
Address:      1 ~ 255
Baud rate:     2400 / 4800 / 9600 / 19200          
/35700 / 38400 / 57600 bps
Data bit:      7 / 8 bits
Calibration:   odd / even calibration
Stop bit:      1 / 2 bits
CRC calibration: low byte ahead / high byte ahead
Data format:    support various data formats

Supportive MODBUS Function Code:
Function Code 1: read loop status 
Function Code 2: read discrete input status
Function Code 3: read keeping register value
Function Code 4: read input register value
Function Code 6: write loop
Function Code 16:write multiple register values

TEL:
0086-24-31217278
0086-24-31217280
Fax:
0086 24 31217293
E-MAIL:
jin.guangshu@microcyber.cn
Address:
17-8 Wensu Street, Hunnan New District, Shenyang, China.